PTC2/3系列二位三通专用电磁阀
时间:2023-5-6 16:41:06 点击数:次 总张数:1张 作者:佚名

1683361245727.png

一、应用范围    (Applications

    它广泛应用在航天、船舶重工、石油化工、工业炉窑、锅炉、给排水、采暖空调、消防设备、干燥设备

食品医疗设备、清洗设备、景观灌溉、喷泉、水厂等管道系统中。.

    ( It is widely used in aerospace, shipbuilding Heavy Industry, petrochemical, industrial furnaces, boilers, plumbing, heating and air conditioning, fire-fighting equipment, drying equipmentFood medical equipment, cleaning equipment, landscape irrigation, fountains, water and other piping systems)。

二、产品特点   ( Features

1683362221099.jpg不锈钢直动式,先导式,动作灵敏,寿命长达50万次;专制线圈不易烧毁;阀安装方向无限制;适用范围广。(Stainless Steel Straight Type, Pilotmovement sensitive, life is 50 million times; autocratic coil easily burned; valve installed on the direction of unrestricted; for a wide range of)。

三、工作原理    (Work

一进一出:常闭式:线圈通电,2通向1,1与3关闭;线圈断电,2与1关闭,1通向3.

常开式:线圈通电,3与1关闭,1通向2;线圈断电,3通向1,1与2关闭。

Entered aNormally closedCoils 2 leads to a1 and 3 closed

Coil power2 and 1 closed1 leads to 3.Always openCoils

3 and 1 closed1 leads to 2Coil power3 leads to a1 and 2 closed

一进二出:线圈通电,1通向2,1与3关闭;线圈断电,1与2关闭,

1通向3。(1 into twoCoils1 leads to 21 and 3 closedCoil power

1 and 2 closedleads to 3。)

二进一出:线圈通电,2通向1,3与1关闭;线圈断电,3通向1,

2与1关闭。(2 into 1Coils2 leads to a3 and 1 closedCoil power

3 leads to a2 and 1 closed。)

注:法兰型工作原理通用(Note: The principle of universal flange type。)

四、圆型、方型、精铸型结构图及规格尺寸

Round, SquareType Casting and specifications of size chart

圆型、方型规格尺寸   (Round,Square size )

1683362565781.jpg12.jpg

精铸型规格尺寸  (Casting Type Size ) 

11.jpg22.jpg

33.jpg

五、主要技术参数  (Main technical parameters

产品型号   Product Type:             

动作方式:直动式□、分步直动式□、先导式□。

Action by: direct-acting type , direct-action step , Pilot .

阀体材质:铸钢体□、不锈钢□。                 

Body material: cast steel body , stainless steel .

控制方式:常开□、常闭□、自保式□。

Control mode: Normally open , NC , self-protection type .                                               

适用介质:水□、气□、油□、蒸汽□、燃气□、腐蚀流体□

Suitable medium: water , gas , oil , steam , gas , corrosive fluid                                                                                                   

工作温度     Operating temperature:                                                

-200℃~0℃□。-60℃~+100℃□。 -20℃~+80℃□。 -20℃~+150℃ □。0℃~+200℃□。0℃~+350℃□.

防护性能:防水□、防爆(Exd IICT5)□、防腐□。

Protection performance: waterproof , explosion-proof (Exd IICT5) , anti-corrosion                                               

☆工作电压       Operating Voltage                                                                                               

DC12V□、DC24V□、DC36V□、DC110V□、DC127V□、DC220V□;AC36V□、AC110V□、AC220V□、AC380V

接线方式:接线座式□、引线式□、插座式□。                                                   

Wiring: Wiring Block type , lead type , socket

附加功能:带信号反馈□、带手动控制□、带止回功能□

Additional features: with signal feedback , with manual control , with a return function

六、安装与维护  Installation and maintenance

安装前应仔细核对阀标牌数据是否符合现场要求,如电压、温度、介质、压力等。

电磁阀现场安装必须按照国家爆炸危险场所“电气安全规程” 中有关规定进行。

电磁阀线圈必须牢固可靠。线圈有三孔插头,其中上为接地线,左右孔接工作导线。

电磁阀安装前应将管路内部清洗干净。 

如果流通的介质中有杂质,电磁阀进口端前必须安装密度0.5μm的过滤网。

安装电磁阀时注意阀体上箭头要求与介质流向一致。

电磁阀水平安装最佳,(线圈在上)。

非电气人员不得拆卸电磁阀电气部件。

Should carefully check the valve before installing signs whether on-site data requirements, such as voltage, temperature, medium, pressure, etc.

Solenoid valve must be installed in accordance with the state explosion site dangerous place, "Electrical Safety Regulations" in the relevant provisions.

Solenoid valve coil must be solid and reliable. Coil with three-hole plug, which on the ground, then work around hole lead.

Solenoid valve installed within the pipe should be cleaned before.

If the flow of medium with impurity, solenoid valve must be installed before the inlet of the filter density of 0.5μm.

Solenoid valve installed on the arrow when the body demands attention with the same media flow.

The level of the best valve installed, (coil on)

Non-electrical personnel shall not be demolished solenoid valve electrical components.

七、常见故障诊断及处理: Fault Diagnosis and Treatment

接通电源,电磁阀不正常工作a 线圈烧毁或短路——更换线圈,b 电源电压过低——调整电压-10%~+10%

范围。c管道内介质压力不符合工作压力范围 ——调整压力或更换压力对应的阀

Switch on the power, electromagnetic valve does not work: a .coil to burn or short circuit -------- replace

the coil,b .power supply voltage is too low ------ adjust the voltage of -10% ~ +10%Range.

C. medium pressure pipeline does not meet the scope of work pressure --- the pressure to adjust the

pressure or the corresponding valve replacement

断开电源,电磁阀不正常工作阀:阀芯被杂质卡住,不能复位——由专业人员拆卸、清除、装配。

Disconnect the power valve solenoid valve does not work: spool is stuck impurities can not reduction --

the professional demolition, removal, assembly

泄漏超标:a阀内有杂物——清除杂物,b密封件损坏或老化——更换密封件,c选型压力不符合工作压力--

更换压力对应的阀。

Excessive leakage: a valve with debris -- debris removal, b seal damaged or aging --replace seals,

c selection pressures do not meet the work pressure ---Pressure corresponding valve replacement